Research local zoning codes for ADU design
Calculate returns and costs to get financing
Estimate your project costs and timeline

Check your property to get started with ADU designs:

I'm interested in


Zoning Guidelines
Zoning
Last Updated 11/15/18

The city government of Citrus Heights has updated its local zoning codes to comply with the State ADU mandate.

Number of ADUs allowed:

No more than one accessory dwelling unit shall be approved on a single parcel. Accessory dwelling units are not included when calculating the density of a parcel.

Types of ADUs allowed:

Attached, Detached or junior ADU. Conversion of existing space or new construction permitted.

Lot size:

Minimum lot size will be determined by the maximum allowed density of the underlying zone.

ADU size:

The floorspace of an attached accessory dwelling unit shall not exceed 60 percent of the floorspace of the primary dwelling or 1,200 square feet , whichever is less. The floorspace of a detached accessory dwelling unit shall not exceed 1,200 square feet , regardless of the size of the primary dwelling. For purposes of computing the floorspace of an accessory dwelling unit, all enclosed areas accessed from within the accessory dwelling unit shall be included. For purposes of computing the floorspace of the primary dwelling, an attached garage of up to 400 square feet may be included when calculating the floorspace of the primary dwelling.

Setbacks:

Setback requirements. An accessory dwelling unit shall comply with the setback requirements of the applicable zoning district. An existing legal accessory structure, including legal non-conforming structures, may be converted to an accessory dwelling unit regardless of height limit, lot coverage, or setbacks. If an existing legal accessory structure, including legal non-conforming structures, is expanded for the purpose of creating an accessory dwelling unit, a minimum five-foot side and rear yard setback shall apply to all sides of the structure. FRONT setback, An accessory structure shall not be located within a required FRONT setback except as may otherwise be provided by Subsection E. Side and REAR setbacks. An accessory structure not exceeding feet in height shall maintain interior side and REAR setbacks of at least five feet; except that the Director may authorize a minimum side and/or REAR setback of three feet. An accessory structure with a height greater than feet shall increase the setback one foot for each foot above feet . (i.e., an 18-foot high structure shall be setback seven feet.) Separation between structures. An accessory structure shall maintain at least a five-foot separation from other accessory structures and the primary dwelling unit. Double-frontage lot. An accessory structure shall not occupy the front half of a parcel, or either front quarter of a double-frontage lot, unless it is setback at least feet from any street lot line. Reverse corner lot. On a reverse corner lot that abuts a key lot, no accessory structure shall be located less than 12. feet from the street property line.

Parking:

Single-family residential. Required parking may be located within the required front and interior SIDE setback provided the required parking occurs on an approved driveway at least feet in length and is perpendicular to the street. Alternate locations may be approved by the Director provided the design of the driveway is aesthetically pleasing, compatible with the surroundings and will not create a pedestrian or vehicular hazard. parking spaces. Each parking space shall be a minimum of nine feet wide and feet long. Compact car spaces with minimum dimensions al eight feet by feet may be allowed within a parking lot interior, up to a maximum of 25 percent of the total number of spaces.

Fire Safety:

Fire sprinklers are not required for the ADU unless they are required for the primary dwelling.

Shape, materials and style:

State Standards don't specify design restrictions.

Height:

Height limit. An accessory dwelling unit shall comply with the height limits of the applicable zoning district except that a detached accessory dwelling unit shall not exceed a maximum height of feet, except when the accessory dwelling unit is above a detached residential accessory structure, in which case it shall not exceed feet.

Design review:

Review and approve, The Zoning Clearance shall be reviewed and a decision determined within 120 days from the day the application is determined complete, The Director shall issue the Zoning Clearance after determining that the request complies with all Zoning Code provisions applicable to the proposed use.

Number of Bedrooms:

Not specified by State Standards.

Ownership:

Unit is not intended for sale separate from the primary residence and may be rented. (State requirements)

Utility connections:

Local health officer approval where a private sewage disposal system is being used, if required. (State requirements)


Estimate ADU Potential
Financing
Costs / ROI

APPRECIATION ESTIMATE

* upon completion of ADU

CONSTRUCTION COST ESTIMATE

* based on local average price per sqft

RENTAL ESTIMATE

* estimated by location

MORTGAGE ESTIMATE

* 30 years / 5% interest rate / 20% down payment

BASED ON LOCAL AVERAGE PROPERTY DATA & VALUE

Appreciation Estimate = (Base Value: $) / (Home's Living Space: sqft) * (ADU's Living Space: sqft)

Rental Estimate = (Rent Per Sqft: $1.93) * (ADU's Living Space: sqft)




Check your property to get started with ADU designs:

Access insights, design tools, and contacts to help you get started with your ADU project, free of charge. Order ADU Services and access the ADU Marketplace to speed up the process.

I'm interested in